90
Sun Fire T2000 Server Service Manual • October 2005
11. Reconnect the cables to the motherboard:
■
The cable marked P8 to the I/O board.
■
The gray ribbon cable that runs along the left side of the chassis.
■
Pull the hard drive data cables through the interior wall of the chassis and
connect them to the SAS controller PCI card. Ensure that you connect the correct
cable to the proper port.
12. Reconnect all cables that were removed from the rear of the server.
13. Perform the procedures described in
“Common Procedures for Finishing Up” on
page 103
.
▼
To Remove the Power Distribution Board
1. Perform the procedures described in
“Common Procedures for Parts
Replacement” on page 67
.
Caution –
The system supplies power to the power distribution board even when
the system is powered off. To avoid personal injury or damage to the system, you
must disconnect power cords before servicing the power distribution board.
2. Disengage both power supplies from the power distribution board.
To disengage a power supply, push the power supply latch to the right and pull the
power supply out a few inches to disengage it from the power distribution board
(
FIGURE 4-17
).
FIGURE 4-17
Location of Power Supply Latch
Power supply latches