Chapter 2
Sun Fire T2000 Server Diagnostics
39
The following example shows a POST error message.
In this example, POST is reporting a memory error at DIMM location
MB/CMP0/CH2/R0/D0
. It was detected by POST running on core 7, strand 2.
b. Run the
showfaults
command to obtain additional fault information.
The fault is captured by ALOM, where the fault is logged, the Service Required
LED is lit, and the faulty component is disabled.
Example:
In this example,
MB/CMP0/CH2/R0/D0
(DIMM 13) is disabled. The system can
boot using memory that was not disabled until the faulty component is replaced.
Note –
You can use ASR commands to display and control disabled components.
See
“Managing Components with Automatic System Recovery (ASR) Commands”
on page 44
.
7:2>
7:2>ERROR: TEST = Data Bitwalk
7:2>H/W under test = MB/CMP0/CH2/R0/D0/S0 (MB/CMP0/CH2/R0/D0)
7:2>Repair Instructions: Replace items in order listed by 'H/W
under test' above.
7:2>MSG = Pin 149 failed on MB/CMP0/CH2/R0/D0 (J1601)
7:2>END_ERROR
7:2>Decode of Dram Error Log Reg Channel 2 bits
60000000.0000108c
7:2> 1 MEC 62 R/W1C Multiple corrected
errors, one or more CE not logged
7:2> 1 DAC 61 R/W1C Set to 1 if the error
was a DRAM access CE
7:2> 108c SYND 15:0 RW ECC syndrome.
7:2>
7:2> Dram Error AFAR channel 2 = 00000000.00000000
7:2> L2 AFAR channel 2 = 00000000.00000000
ok
.#
sc>
showfaults -v
ID
Time FRU
Fault
1 APR 24 12:47:27
MB/CMP0/CH2/R0/D0
MB/CMP0/CH2/R0/D0
deemed faulty and disabled
Summary of Contents for Netra T2000
Page 8: ...viii Sun Fire T2000 Server Service Manual October 2005 ...
Page 14: ...xiv Sun Fire T2000 Server Service Manual October 2005 ...
Page 68: ...54 Sun Fire T2000 Server Service Manual October 2005 ...
Page 122: ...108 Sun Fire T2000 Server Service Manual October 2005 ...
Page 132: ...118 Sun Fire T2000 Server Service Manual October 2005 ...