Netra 1290 Server System Administration Guide • May 2006
■
Might cause the hardware to pause while software analyzes and records the event
error.
■
Determines whether or not the error is recoverable and if the system needs to be
reset.
■
When possible, causes the faulty FRU to provide an LED indication of a fault in
addition to populating the system console messages with further details.
■
Determines if dynamic deconfiguration and reconfiguration is applicable.
If the system cannot diagnose the problem, see the following sections for
troubleshooting information.
Power Distribution
▼
To Troubleshoot the Power Distribution System
1. Ensure that all cabling is properly connected.
2. Check that switch positions are correct on all involved FRUs.
3. Check that the LEDs on the involved FRUs are as indicated in the following
sections.
Normal Operation
The LED status of all FRUs in a properly operating Netra 1290 server is described in
TABLE 4-1
.
TABLE 4-1
FRU LED Status
FRU
LED Status in Standby Mode
LED Status After Power On
Power supplies
Green Power LEDs blinking
All other LEDs off
Power LEDs green
All other LEDs off
System boards
IB_SSC Power LED green
All other LEDs off
Power LEDs green
All other LEDs off
Main fans and fan tray
Fan tray Power LED green
All other LEDs off
Fan tray Power LED green
All other LEDs off
IB fans
All LEDs off
All LEDs off
Hard drives
All LEDs off
Power LEDs green
All other LEDs off
Summary of Contents for Netra 1290
Page 12: ...xii Netra 1290 Server System Administration Guide May 2006...
Page 32: ...14 Netra 1290 Server System Administration Guide May 2006...
Page 48: ...30 Netra 1290 Server System Administration Guide May 2006...
Page 80: ...62 Netra 1290 Server System Administration Guide May 2006...
Page 104: ...86 Netra 1290 Server System Administration Guide May 2006...
Page 112: ...94 Netra 1290 Server System Administration Guide May 2006...
Page 142: ...124 Netra 1290 Server System Administration Guide May 2006...