84
Netra 1290 Server System Administration Guide • May 2006
Note –
Disabled components that have a POST status of
chs
cannot be enabled by
using the
setls
command. Contact your service provider for assistance. In some
cases, subcomponents belonging to a parent component associated with a hardware
error also reflect a disabled status, as does the parent. You cannot re-enable the
subcomponents of a parent component associated with a hardware error. Review the
autodiagnosis event messages to determine which parent component is associated
with the error.
Reviewing Additional Error Information
For servers configured with enhanced-memory SCs (SC V2s), the
showerrorbuffer -p
command shows the system error contents maintained in
the persistent buffer.
However, for servers that do not have enhanced-memory SCs, the
showerrorbuffer
command shows the contents of the dynamic buffer and
displays error messages that otherwise might be lost when your domains are
rebooted as part of the domain recovery process.
In either case, the information displayed can be used by your service provider for
troubleshooting purposes.
/N0/SB0/P3/C1
disabled
-
pass
UltraSPARC-IV+, 1500MHz, 16M ECache
/N0/SB0/P0/B0/L0 disabled - untest 2048M DRAM
/N0/SB0/P0/B0/L2 disabled - untest 2048M DRAM
/N0/SB0/P0/B1/L1 disabled - untest empty
/N0/SB0/P0/B1/L3 disabled - untest empty
/N0/SB0/P1/B0/L0 disabled - untest 2048M DRAM
/N0/SB0/P1/B0/L2 disabled - untest 2048M DRAM
/N0/SB0/P1/B1/L1 disabled - untest empty
/N0/SB0/P1/B1/L3 disabled - untest empty
/N0/SB0/P2/B0/L0 disabled - untest 2048M DRAM
/N0/SB0/P2/B0/L2 disabled - untest 2048M DRAM
/N0/SB0/P2/B1/L1 disabled - untest empty
/N0/SB0/P2/B1/L3 disabled - untest empty
/N0/SB0/P3/B0/L0 disabled - untest 2048M DRAM
/N0/SB0/P3/B0/L2 disabled - untest 2048M DRAM
/N0/SB0/P3/B1/L1 disabled - untest empty
/N0/SB0/P3/B1/L3 disabled - untest empty
.
.
.
CODE EXAMPLE 5-11
showcomponent
Command Output – Disabled Components
(Continued)
Summary of Contents for Netra 1290
Page 12: ...xii Netra 1290 Server System Administration Guide May 2006...
Page 32: ...14 Netra 1290 Server System Administration Guide May 2006...
Page 48: ...30 Netra 1290 Server System Administration Guide May 2006...
Page 80: ...62 Netra 1290 Server System Administration Guide May 2006...
Page 104: ...86 Netra 1290 Server System Administration Guide May 2006...
Page 112: ...94 Netra 1290 Server System Administration Guide May 2006...
Page 142: ...124 Netra 1290 Server System Administration Guide May 2006...