9. Disconnect the I/O cables from the IB_SSC assembly to the removable media
modules (
). Secure the cables out of the way.
FIGURE 10-3
IB_SSC Assembly Cable and Connector Locations
Caution –
Do not disconnect the SSC card reader cable end that connects to the SSC
card reader or the SCSI data cable end that connects removable media backplane.
Those cable ends are soldered and cannot be removed.
10. Remove the I/O cards from the I/O bay.
See
Section 10.2.1, “Removing a I/O Card” on page 10-9
Note –
If you are replacing the power distribution board, you can leave the I/O
cards installed.
DVD-ROM drive
data/power
connector
Disk drive power
cable
SCC card
reader connector
SCSI data
connector