TO ENSURE YOUR USER INFORMATION IS UP TO DATE PLEASE DOWNLOAD THE LATEST VERSION OF THIS MANUAL FROM WWW.SUEX
Page 43 of 48
Figure 13
44.1 O
PERATIONS
THIS DEVICE SHOULD ONLY BE USED WHEN DIVING AND ONLY
IF ONE OF THE TWO FAULTS OCCUR:
1. Despite the switch rotated to the ON position, the ADV does not start when the
trigger is pressed (with the battery charged).
2. Following a collision when diving, the trigger was damaged and can no longer be
used.
IF YOU ARE ABSOLUTELY SURE TO BE IN THE ENVIRONMENTAL AND
PSYCHOLOGICAL CONDITIONS TO MANAGE A SITUATION SUCH AS A
MALFUNCTIONING ADV, PROCEED AS FOLLOWS OR ABANDON THE ADV.
•
Rotate the main switch (6) (see fig.1) counter-clockwise and make sure the ADV
does not start. (TURNING OFF THE ADV)
•
Fully rotate the By Pass knob (50) (see fig. 13) clockwise without forcing.
•
Rotate the main switch (6) clockwise. The ADV starts in continuous mode. If it
does not start, the ADV is broken. Abandon or recover it.
•
Rotate the main switch (6) counter-clockwise to stop the ADV.
Turn the ADV on and off using the main switch without forcing.
In normal operating conditions, the By Pass device knob should be
ALWAYS FULLY
rotated counter-clockwise.
THE BY PASS DEVICE SHOULD ONLY BE USED IF AN ELECTRONIC FAULT
OCCURS AND ONLY DURING A DIVE. DO NOT USE THIS DEVICE AS A NORMAL
STARTING PROCEDURE.
Summary of Contents for XJ37
Page 50: ......