d
e
f
g
h
©
Street
Crane
Co
Ltd
Ref:
D3256
rev.
B
Page
89
of
103
7.5.7
ZX06
Hoist
Motor
Data
–
3:1
SPEED
RATIO
‐
380(±10%)V,
3Ph,
60Hz
Example
from
hoist
model
code
:
ZX064
‐
3
EoN8N
M5
K
03
1
‐
LHR0002
‐
38060
E14X
Hoist
Motor
Speed
Ratio
Motor
Mass
(kg)
Motor
Ratings
at
380V(±10%)
60Hz
BS
Class
CDF
S/h
Power
FLC
LRC
Main
Fuse
Cos
%
kW
A
A
03
3
26
(57lb)
M3
17/8
50/100
3.7/1.2
9.1/5.24
29/16.5
16A
0.87/0.55
M4
20/10
60/120
3.4/1.1
8.1/5.14
0.86/0.52
M5
27/13
80/160
3.1/1.0
7.4/5.07
0.85/0.49
M6
34/17
100/200
2.8/0.9
6.7/5.0
0.83/0.46
M7
40/20
100/200
2.5/0.8
6.1/4.95
0.82/0.43
04
3
30
(66lb)
M3
17/8
50/100
4.7/1.6
12.8/4.8
52/19.4
20A
0.76/0.68
M4
20/10
60/120
4.3/1.4
11.7/4.6
0.75/0.66
M5
27/13
80/160
3.9/1.3
10.8/4.4
0.71/0.63
M6
34/17
100/200
3.5/1.2
10.5/4.3
0.70/0.61
M7
40/20
100/200
3.1/1.0
9.8/4.05
0.67/0.55
05
3
53
(117lb)
M3
17/8
50/100
7.8/2.6
18.5/8.5
87/29
40A
0.83/0.6
M4
20/10
60/120
7.1/2.4
17.2/8.1
0.81/0.58
M5
27/13
80/160
6.5/2.1
15.9/7.8
0.80/0.54
M6
34/17
100/200
5.8/1.9
14.7/7.6
0.77/0.51
M7
40/20
100/200
5.2/1.7
13.8/7.3
0.75/0.47
7.5.8
ZX08
Hoist
Motor
Data
–
4:1
SPEED
RATIO
‐
380(±10%)V,
3Ph,
60Hz
Example
from
hoist
model
code
:
ZX084
‐
4
EoN3A
M6
K
07
1
‐
LHR0002
‐
38060
E14X
Hoist
Motor
Speed
Ratio
Motor
Mass
(kg)
Motor
Ratings
at
380V(±10%)
60Hz
BS
Class
CDF
S/h
Power
FLC
LRC
Main
Fuse
Cos
%
kW
A
A
06
4
50
(110lb)
M3
17/8
50/100
9.1/2.3
22.2/10.9
86/25.9
40A
0.86/0.49
M4
20/10
60/120
8.4/2.1
20.1/10.6
0.80/0.48
M5
27/13
80/160
7.6/1.9
18.9/10.2
0.78/0.42
M6
34/17
100/200
6.8/1.7
16.6/10.2
0.80/0.40
M7
40/20
100/200
6.1/1.5
15.4/10.2
0.76/0.37
07
4
58
(128lb)
M3
17/8
50/100
11.2/2.8
25.7/12.1
100/28
40A
0.83/0.53
M4
20/10
60/120
10.1/2.5
23.6/11.7
0.82/0.50
M5
27/13
80/160
9.2/2.3
21.7/11.4
0.80/0.48
M6
34/17
100/200
8.3/2.1
20.3/11.2
0.79/0.45
M7
40/20
100/200
7.4/1.8
18.8/11.0
0.76/0.41
08
4
98
(216lb)
M3
17/8
50/100
13.0/3.2
32.7/16.6
167/50
63A
0.84/0.44
M4
20/10
60/120
12.0/3.0
31.0/16.4
0.83/0.42
M5
27/13
80/160
10.8/2.7
27.9/16.2
0.83/0.40
M6
34/17
100/200
9.7/2.4
26.4/16.0
0.82/0.37
M7
40/20
100/200
8.6/2.2
24.8/15.8
0.80/0.35
10
4
120
(265lb)
M3
17/8
50/100
19.2/4.8
TBA
TBA
M4
20/10
60/120
17.6/4.4
M5
27/13
80/160
16.0/4.0
TBA
TBA
M6
34/17
100/200
14.4/3.6
M7
40/20
100/200
12.8/3.2
CDF
=
Cyclic
duration
factor
(%ED),
S/h
=
Motor
starts
per
hour,
FLC
=
Motor
full
load
current,
LRC
=
Locked
rotor
current,
Cos
=
Power
factor.
The
motors
are
designed
for
the
voltage
range
shown.
The
hoist
motor
2
pole
starting
current
and
the
rated
current
of
the
travel
motor
are
used
in
selecting
the
recommended
main
fuse
size.
Main
fuses
are
type
gL/gG.
Fuse
size
in
(parentheses)
are
for
class
‘J’
fuses
for
CSA
(CSA
‐
22.2)
approved
installations.
Summary of Contents for ZX6
Page 2: ......
Page 4: ...defgh Street Crane Co Ltd IV THIS PAGE IS INTENTIONALLY BLANK ...
Page 99: ...defgh Street Crane Co Ltd Ref D3256 rev B Page 99 of 103 NOTES ...
Page 100: ...defgh Street Crane Co Ltd Page 100 of 103 Ref D3256 rev B NOTES ...
Page 101: ......
Page 102: ......