3.2
RUNNING
&
MOUNTING
SURFACE
TOLERANCES
AND
FINISHES
3.2.1
Tolerances
on
the
Inclination
of
the
Running
Surface
The
angle
of
inclination
of
the
running
surface
for
the
hoist
should
not
exceed
the
values
shown.
3.2.2
Tolerances
on
Crab
Rail
Gauge
&
Rail
Height
The
gauge
shall
not
deviate
from
the
nominal
by
more
than
3mm.
The
difference
in
rail
height
shall
not
exceed
3mm
for
gauges
up
to
and
including
2000mm
or
5mm
for
gauges
greater
than
2000mm.
Rail
height
should
be
a
minimum
of
30mm.
3.2.3
Tolerances
on
Single
Girder
Runway
Flange
Width
The
variation
in
the
width
of
a
single
girder
runway
flange
should
be
no
greater
than
3mm
over
its
entire
length.
3.2.4
Tolerances
on
Mounting
Surface
for
Foot
Mounted
Hoists
The
vertical
misalignment
between
all
mounting
holes
shall
not
exceed
1mm.