A noncombustible floor protection with R value insulation equal to or greater than 1.00 must be installed in
front of the unit up to 20". For more details see
Section 6.3.2:
Minimum Hearth Extension Requirements
.
The use of an R value is convenient when more than one material is going to be used in the hearth
extension to cover the combustible surface. This is because R values are additive, whereas K values are not.
To find the corresponding R factor to use for some selected materials, please see
Thermal Characteristics of
Common Floor Protection Materials
table.
CAUTION: DO NOT LEAVE CARPET UNDER THE FLOOR PROTECTION IN FRONT OF THE FIREPLACE
6.3.1.3
R Calculations
There are two ways to calculate the R factor of the floor protection. First, by adding the R-values of the
proposed materials or if some K and thickness values are given, by converting them to R values.
To calculate the R factor for a composite floor protection made of a combination of alternative materials,
simply add the R-values of those materials. If the result is equal to or larger than the required R value, the
combination is acceptable. For R-values of some selected materials, see Appendix section.
Example:
Required floor protection R of 1.00. Proposed materials: four inches of brick and one inch of
Durock
®
board:
Four inches of brick
(R = 4 x 0,2 = 0,8) plus 1 inch of Durock
®
(R = 1 x 0.52 = 0.52).
0.8 + 0.52 = 1.32.
This R value is larger than the required 1.00 and is therefore
acceptable
In the case of a known K and thickness of alternative materials to be used in combination, convert all K
values to R by dividing the thickness of each material by its K value. Add the R values of your proposed
materials as shown in the previous example.
Example:
K value = 0.75
Thickness = 1
R value = Thickness/K = 1/0.75 = 1.33
Summary of Contents for VB00003
Page 10: ...10 HE200 Installation and Operation Manual 6 142mm FORCED AIR DISTRIBUTION KIT 3...
Page 36: ...36 HE200 Installation and Operation Manual...
Page 56: ...56 HE200 Installation and Operation Manual Direct installation Exterior offset installation...
Page 89: ...HE200 Installation and Operation Manual 89 APPENDIX 7 EXPLODED DIAGRAM AND PARTS LIST...