HE200 - Installation and Operation Manual
2
GENERAL INFORMATION ON HE200 (VB00003)
2.1 Appliance performance
(1)
Fuel type
Dry cordwood
Recommended heating area
[*]
500 to 1,900 ft
2
(46 to 177 m
2
)
Firebox volume
2.3 ft
3
(0.065 m
3
)
Maximum burn time
[*]
8 h
Maximum heat output (dry cordwood)
(2)
65,000 BTU/h (19.0 kW)
Overall heat output rate (min. to max.)
(2)(3)
10,600 BTU/h to 36,400 BTU/h (3.1 kW to 10.7 kW)
Average overall efficiency
(3)
- EPA Cribs / Douglas
Fir
63.1% (HHV
(4)
)
68.2% (LHV
(5)
)
Average overall efficiency
(3)
- Dry cordwood
To come (HHV
(4)
)
To come (LHV
(5)
)
Optimum efficiency
(2)(6)
75.0%
Average particulate emissions rate
(7)
4.0 g/h (EPA / CSA B415.1-10)
Average CO
(8)
119.3 g/h
[*]
Recommended heating area and maximum burn time may vary subject to location in home, chimney draft, heat loss
factors, climate, fuel type and other variables. The recommended heated area for a given appliance is defined by the
manufacturer as its capacity to maintain a minimum acceptable temperature in the designated area in case of a
power failure.
(1)
Values are as measured per test method, except for the recommended heating area, firebox volume, maximum burn
time and maximum heat output.
(2)
The maximum heat output (dry cordwood) is based on a loading density varying between 15 lb/ft
3
and 20 lb/ft
3
.
Other performances are based on a fuel load prescribed by the standard. The specified loading density varies
between 7 lb/ft³ and 12 lb/ft
3
. The moisture content is between 19% and 25%.
(3)
As measured per CSA B415.1-10 stack loss method.
(4)
Higher Heating Value of the fuel.
(5)
Lower Heating Value of the fuel.
(6)
Optimum overall efficiency at a specific burn rate (LHV).
(7)
This appliance is officially tested and certified by an independent agency.
(8)
Carbon monoxide.
Summary of Contents for VB00003
Page 10: ...10 HE200 Installation and Operation Manual 6 142mm FORCED AIR DISTRIBUTION KIT 3...
Page 36: ...36 HE200 Installation and Operation Manual...
Page 56: ...56 HE200 Installation and Operation Manual Direct installation Exterior offset installation...
Page 89: ...HE200 Installation and Operation Manual 89 APPENDIX 7 EXPLODED DIAGRAM AND PARTS LIST...