86
HE200 - Installation and Operation Manual
6.
Insert a retaining support in the last
hole on the left of the secondary air
tube. With a hexagonal 1/4"/7mm
socket, screw the retaining support
in the appropriate hole of the
channel. Install the baffle then
repeat
steps 4, 5 & 6
for the
remaining tubes.
To remove the tubes, follow the steps in
reverse order.
Note that
secondary air tubes can be replaced without removing the baffle board.
Important Notes:
The air tubes are identified for placement as follows:
Model
Type of tube
HE200 fireplace
Front
►
59 holes of 0.93"
Middle
►
57 holes of 0.093"
Rear
►
55 holes of
0.093’’