1.
Position the fireplace in its location. Temporarily
install the elbow or chimney section (A) on the
top of the fireplace and, using a level, mark with
an oval the location where the liner will enter the
masonry chimney.
2.
In the middle of the oval, drill a hole in the
masonry chimney at 45
or 30
.
3.
Increase the size of the hole so that the liner with
the 45
or 30
insulated liner adapter (B) around
can be easily slipped through.
4.
Install a CACLF6 (Forever Flex) or CUCHF6
(Hybrid)
on the liner and slide the liner (C) down
from the top of the masonry chimney until you
reach the hole level.
5.
Install the CVA-CPEC06 on the elbow or chimney
section.
6.
Slide
the
liner
assembled
with
the
CACLF6/CUCHF6 through the hole performed in
Step 2
.
7.
Install the insulation of the insulated liner
adapter over the liner.
8.
Insert the stainless steel tube of the insulated
liner adapter over the insulation.
9.
Connect the CACLF6/CUCHF6 to the CVA-CPEC06.
10.
Seal the joint between the insulated liner
adapter and the CVA-CPEC06.
11.
Seal the opening in the masonry chimney around the insulated liner adapter with high temperature
refractory cement.
12.
To complete installation, secure the elbow or chimney section to the fireplace anchor plate.
Note:
Make sure the liner exceeds at least 12” (30 cm) the top of masonry chimney
.
CVA-UMA0630/
CVA-UMA0645
CACLF6/
CUCHF6
CVA-CPEC06
Summary of Contents for VB00003
Page 10: ...10 HE200 Installation and Operation Manual 6 142mm FORCED AIR DISTRIBUTION KIT 3...
Page 36: ...36 HE200 Installation and Operation Manual...
Page 56: ...56 HE200 Installation and Operation Manual Direct installation Exterior offset installation...
Page 89: ...HE200 Installation and Operation Manual 89 APPENDIX 7 EXPLODED DIAGRAM AND PARTS LIST...