72
HE200 - Installation and Operation Manual
The duct system must be installed respecting the following:
1.
It is recommended to
wear gloves to perform
this procedure. Remove
the plates closing up the
8" dia. holes on top of
the fireplace. Then, cut
and
remove
the
insulation in order to
obtain
two
8"
dia.
openings. Then, remove
the plates closing up the
8" dia. holes inside the
fireplace.
2.
Secure the 2 anchor
plates (C) with 8 screws
provided (B) on top of
the fireplace (4 for each
anchor plate). Insert the
telescoping section (A)
into each anchor plate
and secure it with 6 other
self-tapping
screws
provided (B).