HE200 - Installation and Operation Manual
69
8.
Do not connect the hot ai
r ducts to a central heating system. Malfunction of the heating system’s fan
will cause the fireplace to overheat.
9.
Do not use insulated flexible ducts as they may overheat.
10.
Do not use tees or any other components than the ones specifically listed here.
11.
All ducts must extend upwards or horizontally.
Never route the ducting downwards
.
12.
The hot air outlet grilles must be installed with the louvers pointing downwards in order to prevent
overheating adjacent ceilings.
13.
Always install the two outlet grilles when using the hot air gravity distribution kit and blocking the upper
louver of the fireplace.
Hot air gravity distribution
kit - Modern with adjustable pipes (AC01389)
The kit includes:
-
Decorative plate (A)
-
Adjustable frame (B)
-
Heat distribution box (C)
-
Telescoping section (D)
-
Anchor plate (E)
-
All screws are included
Parts not included in the kit:
-
8” rigid ducting (if required
according to the desired height).