40
HE200 - Installation and Operation Manual
Thermal Characteristics of Common Floor Protection Materials*
MATERIAL
CONDUCTIVITY (k)
PER INCH
RESISTANCE (R) PER INCH
THICKNESS
Micore
®
160
0.39
2.54
Micore
®
300
0.49
2.06
Durock
®
1.92
0.52
Hardibacker
®
1.95
0.51
Hardibacker
®
500
2.3
0.44
Wonderboard
®
3.23
0.31
Cement mortar
5.00
0.2
Common brick
5.00
0.2
Face brick
9.00
0.11
Marble
14.3
–
20.00
0.07
–
0.05
Ceramic tile
12.5
0.008
Concrete
1.050
0.950
Mineral wool insulation
0.320
3.120
Limestone
6.5
0.153
Ceramic board (Fibremax)
0.450
2.2
Horizontal still air** (1/8")
0.135
0,920**
* Information as reported by manufacturers and other resources.
** For a 1/8" thickness. You cannot «stack» horizontal still air to accumulate R-values; you must separate
each layer of horizontal still air with another non-combustible material.
Summary of Contents for VB00003
Page 10: ...10 HE200 Installation and Operation Manual 6 142mm FORCED AIR DISTRIBUTION KIT 3...
Page 36: ...36 HE200 Installation and Operation Manual...
Page 56: ...56 HE200 Installation and Operation Manual Direct installation Exterior offset installation...
Page 89: ...HE200 Installation and Operation Manual 89 APPENDIX 7 EXPLODED DIAGRAM AND PARTS LIST...