Repairing the knitting machine
7
Check fuses 7.5
352
4. Check the battery fuse (7) on the control unit.
Battery fuse below the power supply unit
5. Check the ballast fuse (5) on the right control unit . For this purpose,
remove the screws at the top and bottom and pull out the board.
Ballast fuse for servo drive and racking on the control unit
DANGER
Burning risk!
Injuries by hot parts.
➜
Watch out not to touch the resistors (6) when pulling out
the board. The resistors can get very hot.