Setup Data
5
Setup2 Editor 5.4
256
5.4.5
Carriage speed
Different carriage speeds can be entered for different knitting situations.
The indirect carriage speed only becomes effective when it is slower than
the normal speed.
Further information:
Comparing Setup1 to Setup2 [-> 235]
Explanation
Value range
(meters/second)
MSECK
Carriage speed for small knots over m rows,
standard: 1 row
Minimum value: 0.05
Maximum value: 1.20
Step width: 0.05
MSEC
Speed
(normal speed)
Minimum value: 0.05
Maximum value: 1.20
Step width: 0.05
MSEC0
Speed for empty rows (S0)
Minimum value: 0.05
Maximum value: 1.40
Step width: 0.05
MSEC1
Speed for transfer rows
Minimum value: 0.05
Maximum value: 1.20
Step width: 0.05
MSECI
Speed with Intarsia Yarn Carrier
Minimum value: 0.05
Maximum value: 1.00
Step width: 0.05
MSECC
Speed outside the needle bed when the yarn
carrier is brought in the clamp or taken out of
the clamp.
Minimum value: 0.05
Maximum value: 0.50
Step width: 0.05
MSEC2-20 Speed for knitting rows
Minimum value: 0.05
Maximum value: 1.20
Step width: 0.05
Comment
Comment
ASCII Characters
Summary of Contents for CMS ADF-3
Page 16: ...About this document 1 Warnings in the documentation 1 5 16...
Page 232: ...Adjusting knitting machine 4 Defining user profile 4 6 232...
Page 270: ...Setup Data 5 Setup1 Editing the setup file 5 5 270...
Page 296: ...Maintenance of the knitting machine 6 Lubricate knitting machine 6 3 296...
Page 410: ...Software Installation and basic settings 8 Diagnose Control 8 5 410...
Page 436: ...Machine Management Tools 10 Send email directly from the machine 10 4 436...
Page 444: ...Key word directory 11 444...