Setup Data
5
Setup2 Editor 5.4
254
YPI (tab)
Plating indices for autarkic yarn carriers (ADF):
Control the insertion position of the basic yarn.
Control the insertion angle of the basic yarn
Shifted insertion positions
Explanation
Value range
YPI
Plating index
Defines the distance between
the yarn carrier and the normal
yarn insertion position in the
needles and the insertion angel.
Insertion position
Horizontal shifting of the
insertion position (x)
Positive value: Following
basic yarn.
The thread is inserted in the
needles later on.
Standard: 6.5 mm
Negative value: Leading
plating yarn
Standard: 0 mm
Minimum value: -100 mm
Maximum value: 100 mm
Step width: 0.1 mm
Height
Shifting in height (y)
Corrects the insertion angle
Positive value: Steeper yarn
angle
Standard: 0.9 mm for the
following basic yarn
Negative value: Flatter yarn
angle
Minimum value: -2 mm
Maximum value: 5 mm
Step width: 0.1 mm
<<
>>
Carriage Direction
The plating index depends on
the carriage direction.
Comment