23
AFTER SALES SUPPORT
1300 886 649
AUS
MODEL: STR-PGGC75 PRODUCT CODE: 10288 09/2019
Installation (Cont.)
Gas tap maintenance
IMPORTANT:
These maintenance operations MUST ONLY be carried out
by a registered gasfitter.
IMPORTANT:
Before carrying out any maintenance operations,
disconnect the appliance from the gas and electricity supplies.
If a gas tap becomes stiff to operate, then you should proceed as follows:
• Remove the control knobs, trivets, burners, hob fixing screws and
mounting brackets.
• Remove the hob from the worktop and remove any protective covers from
the underside.
• Disconnect the fixings holding the tap to the fascia panel and separate the
assembly. Then clean the cone and seating with a cloth dampened with
solvent.
• Lightly smear the cone with high temperature grease, reassemble into
position and rotate a few times.
• Remove the cone again and remove any excess grease, making sure that
the gas ducts are not obstructed with grease.
• Carefully reassemble the components and perform a gas soundness test.
If it becomes necessary to replace a gas tap, then you should proceed as
follows:
• Remove the control knobs, trivets, burners, hob fixing screws and
mounting brackets.
• Remove the hob from the worktop and remove any protective covers from
the underside.
• Disconnect the fixings holding the tap to the fascia panel and separate the
assembly.
• Disconnect the gas pipe from the gas tap, and then disassemble them from
the gas rail by removing the fixing screws.
• When fitting a new tap, ensure that a new gasket is used.
• Reconnect the gas tap, perform a gas soundness test, and then
reassemble the hob.