Error messages
Fault code table
The table provides you with an overview of the
possible displays. The "Comment" column
contains information about the procedure to
follow when the corresponding messages are
displayed.
Message text (German) /
Error code
Display animation
Comment
OVERHEATING
A5022
Cyclic display every
30 sec
Traction motor(s) is/are too hot.
1. Phase: Regulation of acceleration and
speed
2. Phase: Limitation of phase current in
converter (emergency driving function is
maintained).
Fault is automatically cancelled as soon as
the temperature drops below the limit.
If the fault occurs repeatedly, contact your
service centre.
PARAMETERS
A1206
A1211
Cyclic display every
30 sec
Traction and hydraulic drives not functioning
Contact your service centre.
ACCELERATOR
A3002
A3003
A3004
A3005
A3006
A3007
Cyclic display every
30 sec
Sensor fault, vehicle cannot be driven.
Contact your service centre.
ACCELERATOR
A3811
Cyclic display every
30 sec
Accelerator configuration incorrect. Vehicle
cannot be driven.
Contact your service centre.
BRAKE
A3016
A3017
Cyclic display every
30 sec
Sensor fault, vehicle can only be driven at
crawling speed.
Contact your service centre.
KONFIGURATION
(CONFIGURATION)
A2111
Cyclic display every
30 sec
Programming error or defective printed
circuit board, traction and hydraulic drive
not functioning.
Contact your service centre.
KONFIGURATION
(CONFIGURATION)
A3801
Cyclic display every
30 sec
Programming error, traction and hydraulic
drive not functioning.
Contact your service centre.
171673 [EN]
139
Summary of Contents for R70-40T
Page 2: ......
Page 11: ...1 Foreword ...
Page 18: ...1 Foreword Environmental considerations 8 171673 EN ...
Page 19: ...2 Introduction ...
Page 25: ...Introduction 2 Residual risk 171673 EN 15 ...
Page 29: ...3 Safety ...
Page 49: ...4 Overviews ...
Page 51: ...Overviews 4 General view 171673 EN 41 ...
Page 63: ...5 Operation ...
Page 186: ...5 Operation Shut down 176 171673 EN ...
Page 187: ...6 Maintenance ...
Page 248: ...6 Maintenance 3000 hour maintenance two year maintenance 238 171673 EN ...
Page 257: ...7 Technical data ...
Page 265: ...8 Circuit diagrams ...
Page 266: ...8 Circuit diagrams Hydraulics Hydraulics Hydraulic circuit diagram 7071_003 083 256 171673 EN ...
Page 280: ...8 Circuit diagrams Electrical equipment 270 171673 EN ...
Page 287: ......
Page 288: ...Still GmbH Berzeliusstrasse 10 D 22113 Hamburg Ident no 171673 EN ...