![Still R70-40T Operating Instructions Manual Download Page 106](http://html.mh-extra.com/html/still/r70-40t/r70-40t_operating-instructions-manual_1379960106.webp)
5
Operation
Lifting
7071_003-059
3
2
Triplex mast (special equipment)
When the "lift-lower" operating lever is moved
backwards, the inner cylinder moves up to
(3)free lift, and then the outer cylinders directly
raise the inner mast up to the max. (2)height.
NOTE
When raising above the free lift, the fork carri-
age always remains at the upper edge of the
extending mast tip.
DANGER
Risk of accident!
With low ceilings, be aware that the carried load can
project over the fork carriage. The fork carriage can
be higher than the load.
Malfunction during a lifting operation
Incorrect extension sequence
DANGER
Risk of accident!
In the case of triple masts (special equipment), an
incorrect extension sequence can occur, i.e. the in-
ner mast extends before the free lift is complete. As
a result, the overall height is exceeded and damage
may occur with passageways or low ceilings.
An incorrect extension sequence may, for
instance, result from:
• The hydraulic oil temperature being too low.
• Blocking of the fork carriage in the inner
mast.
• Blocking of the free lift cylinder.
• Blocking of the chain roller for the free lift
cylinder.
– If the hydraulic oil temperature is too low,
slowly actuate the mast functions several
times in order to raise the oil temperature.
In the event that the fork carriage in the inner
mast, the free lift cylinder or the chain roller for
the free lift cylinder is blocked, the cause of the
blocking must be eliminated before you can
continue with work.
96
171673 [EN]
Summary of Contents for R70-40T
Page 2: ......
Page 11: ...1 Foreword ...
Page 18: ...1 Foreword Environmental considerations 8 171673 EN ...
Page 19: ...2 Introduction ...
Page 25: ...Introduction 2 Residual risk 171673 EN 15 ...
Page 29: ...3 Safety ...
Page 49: ...4 Overviews ...
Page 51: ...Overviews 4 General view 171673 EN 41 ...
Page 63: ...5 Operation ...
Page 186: ...5 Operation Shut down 176 171673 EN ...
Page 187: ...6 Maintenance ...
Page 248: ...6 Maintenance 3000 hour maintenance two year maintenance 238 171673 EN ...
Page 257: ...7 Technical data ...
Page 265: ...8 Circuit diagrams ...
Page 266: ...8 Circuit diagrams Hydraulics Hydraulics Hydraulic circuit diagram 7071_003 083 256 171673 EN ...
Page 280: ...8 Circuit diagrams Electrical equipment 270 171673 EN ...
Page 287: ......
Page 288: ...Still GmbH Berzeliusstrasse 10 D 22113 Hamburg Ident no 171673 EN ...