09 TRUCK COMPUTER ATC
38
User id:
?
4)
Enter your unique start code.
Code :
????
5)
Use
to scroll down in the parameters menu. Press
for parameters that are to be changed, and the numeric
keys to change the value. Save the selections with
.
Maximum speed
100
Parameter
Description
Instr. range
Maximum speed
Maximum permitted drive
speed
[20 - 100%]
Acceleration dri
Maximum acceleration
[0 - 100%]
Reduc.brakes dri
Motor braking when the
speed controller is
released
[0 - 100%]
Reverse braking
Motor braking when the
direction changes
[50 - 100%]
Soft Hydraulics
Gentler hydraulic control
[0/1] (off/on)
NOTE!
It is only possible to set the parameters for the
normal direction. The parameters for sideways
driving cannot be altered.
6)
When all the parameters have been gone through, press
and
to exit the Service menu.
7)
Log on to the truck and test drive.
Trucks equipped with options
Height preselection
Basics
The height pre-set function can be used as an aid when one
often loads in and out of pallet racks with one or more height
levels. By using pre-set height levels it is easy to lift the forks to
an exact height that suits the pallet rack's positions. When the
driver is to withdraw a pallet from the pallet rack, the forks are
lifted to the selected level using the height pre-set function.
When the driver is to place a pallet, the forks are lifted 10
centimetres higher than the corresponding collection level.
Instruction Handbook UFW — D008453, B, GBR, ForTranslation