8
Field width
Field height
Lip (Collector covering)
Collector field dimensions
Collectors which are mounted
side by side in one row are always
connected by means of stainless
steel expansion joints on the
manifolds (see photo).
It is possible to assemble metal sheets between the collectors to achieve a homogeneous appearance of the installation.
The distance metal sheets are assembled exclusively for optical aspects and do not have any influence on the installation.
Therefore the distance metal sheets can be ordered optionally and are not necessarily included in delivery.
Horizontal section across a collector field
Vertical section across a collector field
In case of multi-row installations, the
collectors will always be mounted
on joint on top of each other. The
lip (collector covering) of the upper
collector has to be put onto the lower
collector. The lip (collector covering)
of the lower collector has to be
clamped into the joint area to ensure
an optimum water flow.
1300002 Collector connection set hydraulical