13
Crushed part
Cut for the supporting
screw
Assembly of the roof-tile clamps
Completely tiled roof
When mounting the roof in regions with high snow
load zone of more than 2 kN/m², it is necessary to
place the roof hooks in the rafter.
Mount the tile clamp support 80 x 270 x 30 mm and fix it with
two screws 5 x 60 mm.
The lath obligatorily has to be placed in such a way
that the hook can be mounted at the lowest point.
The lower roof-tile must be remounted.
Prior to covering, the lower roof-tile must be grounded coarsely.
To avoid a break of the tile, the roof must not rest on the tile.
1410002 Roof-tile clamp V2 without lead
Removal of the tiles after previous determination of the
placement of the roof-tile clamps (see page 11 „Spacing multi-
row collector fields“).
Fixation of the lower lath 24 x 80 x 600 mm with two screws
5x60 mm.
If the lath is placed near the counter lath, the lath
24 x 80 x 600 mm must not be applied.