8
| STERO UNDERCOUNTER DISHWASHER & GLASSWASHER
ELECTRICAL CONNECTION
Electrical and grounding connections must comply with the applicable portions of
the National Electrical Code and/or other local electrical codes.
Disconnect the electrical power to the machine and follow lockout/tagout proce-
dures.
ELECTRICAL DATA
Complied in accordance with the National Electrical Code NFPA-70, latest addition.
For supply connections, use copper wire only rated at 90°C minimum.
Model
Volts/Hertz/Phase
Minimum Supply
Circuit Conductor
Ampacity
Maximum
Protective Device
Ampacity
SU-L
120/60/1
20
20
SU-H
120/208-240
(3W)/60/1*
40
40
SG
120/60/1
20
20
* The (3W) systems require three power wires that include a current carrying neutral. An additional fourth
wire must be provided for machine ground.
Refer to the data plate on the door handle of the machine and the electrical label on the back side of the
lower front panel for proper selection.
CONNECTION METHOD
1. Remove the lower front panel by removing the two screws at the bottom of the panel (Figure 1).
2. Open door of dishwasher and remove the two left screws and the top right screw (Figure 2). Pull top of
unit forward approximately 1" and remove the left side panel.
INSTALLATION
(continued)
Figure 1
Figure 2
REMOVE TWO SCREWS
REMOVE THREE SCREWS