14
| STERO UNDERCOUNTER DISHWASHER & GLASSWASHER
INSTALLATION
(continued)
Required flowing water pressure to the dishmachine is
15-65 PSIG. If pressures higher than 65 PSIG are present,
a pressure regulating valve must be installed in the
water line to the dishmachine (by others).
Pressure gauge not required on pumped rinse machines.
Important: The chemical containers should be placed no
higher than 24" above floor.
If chemical containers are to be placed in cabinet
adjacent to machine, a 1/2" dia. hole is required in the
cabinet to run chemical supply line.
Use only 6% or 8.4% sodium hypochlorite (liquid bleach)
as sanitizing chemical to insure proper operation of
dishmachine.
Certain materials, including silver plate, aluminum and
pewter are attacked by sodium hypochlorite (liquid
bleach). See instructional manual.
Electrical and grounding connections must
comply with the applicable portions of the
National Electrical Code and/or other local
electrical codes.
Plumbing connections must comply with
applicable sanitary, safety and plumbing codes.
Drain and fill line configurations vary, some
methods are shown on this drawing.
CONNECTION INFORMATION
(AFF = ABOVE FINISHED FLOOR)
LEGEND
E1 ELECTRICAL CONNECTION: 1-3/8" DIA. HOLE FOR
1" TRADE SIZE CONDUIT; 18-1/8" AFF
P1 SINGLE FILL AND RINSE CONNECTION: 3/4"
FEMALE GARDEN HOSE FITTING ON 6' LONG HOSE
SUPPLIED WITH MACHINE; 120°F WATER MIN.
FOR SG, 140°F RECOMMENDED.
P2 DRAIN CONNECTION: 5/8" BARB FITTING WITH
6' LONG HOSE SUPPLIED WITH MACHINE.
NOTES:
1. All vertical machine dimensions taken from
floor may be increased by .875" or decreased
by .375".
2. Moist air escapes from the door.
Use only moisture resistant materials
adjacent to dishmachine sides and top.
3. A vent hood is not recommended above the
undercounter dishmachine since it does not
produce excessive vapors.
PLUMBING NOTES:
1. Water hammer arrestor (meeting
ASSE-1010 Standard or equivalent) to be
supplied (by others) in common water supply
line at service connection.
2. Recommended water hardness to be 3 grains
or less for best results.
3. If drain hose is looped above a sink, the loop
must not exceed 51" AFF.
Do not premix other chemicals and sodium
hypochlorite (liquid bleach).
Mixing may cause hazardous gas to form.
MODELS:
SG 42"
00-950420
REV C
FLOOR LINE
RECOMMENDED
31" OR LESS
RECOMMENDED WATER SERVICE
ROUGH-IN 1/2" TRADE SIZE PIPE
MIN. W/SHUTOFF VALVE, LINE
STRAINER & 3/4" MALE GARDEN
HOSE FITTING (BY CUSTOMER).
DETERGENT,
RINSE-AID,
CHLORINE
SANITIZER
BOTTLES MAY
BE LOCATED
UNDER THE
MACHINE
E1
P2
3
1-1/2" TRADE SIZE
PIPE MIN. REDUCED
DOWN TO 3/4" FPT
CONNECTION (BY
CUSTOMER)
23 15/16"
21 11/16"
P2
E1
P2
P1
WALL
13 15/16"
42 1/8"
48 11/16"
SERVICE
CLEARANCE
MIN
ADDITIONAL CLEARANCE REQUIRED TO
SLIDE UNIT FORWARD FOR SERVICE ONLY
SG42 UNDERCOUNTER GLASSWASHER INSTALLATION DIAGRAM
21 11/16"
1 3/8"
26 11/16"
39 9/16"
41 11/16"
24 1/2"
27 3/4"
12" MAX
LOADING