STERO UNDERCOUNTER DISHWASHER & GLASSWASHER |
15
Parameter
Name
Description
Possible
Values
Default
Value
Detergent
Pump
Enables or disables the detergent pump.
Disabled or
Enabled
Enabled
Rinse Aid
Pump
Enables or disables the rinse aid pump.
Disabled or
Enabled
Enabled
Wash Cycle
Sets the cycle duration.
Light, Normal,
or Heavy
Normal
Low Temp
Alarms
(SU-H
Model Only)
Enables or disables a visual alert on the display that indi-
cates that the Final Rinse water temperature is below the
required minimum of 180°F (82°C). When enabled, a mes-
sage will display notifying the user of this condition after
three consecutive cycles do not reach the required final rinse
temperature. However, machine operation will not change
and ware will continue to wash as expected. After the tem-
perature increases past the minimum, the message stops.
When disabled, there will be no extra message indicating a
low temperature event; however, the temperature display
will still show the current Final Rinse water temperature.
Disabled or
Enabled
Disabled
Delime
Enables or disables the alert to delime option.
Disabled or
Enabled
Enabled
Temperature
Units
Sets the display units to either Fahrenheit or Celcius.
Fahrenheit or
Celsius
Fahrenheit
Add
Chemical
Alert
Enables or disables an audible alert if chemical is not being
detected.
Disabled,
Visual, or
Audio and
Visual
Audio and
Visual
End Cycle
Audio Alert
Enables or disables an audible alert at the end of a cycle.
Disabled or
Enabled
Disabled
Language
Sets the language on the display to either English or French.
English (US) or
French
(Canada)
English (US)
Exit Menu
Press ENT to exit the Parameters Menu and return to the
Manager Menu. Any settings that were changed are saved.
PARAMETERS MENU TABLE