Faults
Fault 210: Ambient Temperature Is High
Indicates that the ambient temperature is above the alarm set-point (default 100° F).
Causes
Troubleshooting
Fixes
• Ambient temperature is high.
• Compare reading to actual
ambient temperature.
• Reconsider using the DewPoint
at these temperatures.
• Stop baling if internal bale
temperatures reach more than
135° F.
• Heat from tractor is causing
the sensor to read higher than
normal.
• Compare reading to actual
ambient temperature.
• Adjust the tractor heat offset
by touching the ambient
temperature icon on the touch
screen (default is 10° F).
• Faulty sensor.
• Compare reading to actual
ambient temperature.
• Replace sensor.
• Faulty wiring.
• Inspect the wiring for ground,
continuity, and proper voltage.
• Replace/Repair wiring.
Fault 211: Furnace Door Temp Is High
Indicates that the rear furnace door is above 250° F (Version 3.3/2.6 and older).
Indicates that the rear furnace door is above 170° F (Version 3.4/2.7 and newer).
Causes
Troubleshooting
Fixes
• Failed insulation board / rope
gaskets.
• Check the rear furnace door for
paint bubbling and discoloration
from excessive heat.
• Replace rear furnace door
insulation and rope gaskets.
• Temperature is above 170° F
(Version 2.7 & 3.4).
• Temperature is above 250° F
(Earlier versions).
• Use infrared thermometer to
check rear furnace door.
• Check the rear furnace door for
paint bubbling and discoloration
from excessive heat.
• Replace rear furnace door
insulation and rope gaskets.
• Faulty sensor.
• Use infrared thermometer to
check rear furnace door area
for normal temperatures (below
170° F for versions 2.7 & 3.4 |
below 250° F for earlier versions).
• Replace sensor.
Fault 212: Low Water 2 Tripped
• See “Fault 300: Low Water 1 or 2 Tripped”.
Fault 213: Boiler Taking Longer Than Expected to Fill
• See “Fault 300: Low Water 1 or 2 Tripped”.