143
Faults
Fault 201: Turn Burner Switch ON
Indicates that the burner is not getting 120 V power (See 120 V Control Power page).
Causes
Troubleshooting
Fixes
• Burner door switch is “OFF”.
• Turn the switch to “ON”.
• Circuit breaker B6 is tripped
(Panel 1).
• Reset the circuit breaker.
• Main generator circuit breaker
is tripped/faulty.
• Reset/Replace the circuit breaker (Part #10207).
• Generator plug disconnected.
• Connect generator plug to burner.
• Faulty generator end.
• Check generator output voltage
(see Test 16).
• Replace voltage regulator.
• Replace generator.
• Faulty SR-1 relay: Part #10269.
• Swap relay with 120 V spare in
Panel 1.
• Replace SR-1 relay in Panel 1.
• Faulty burner door switch.
• Test switch continuity with
multimeter.
• Replace burner door switch.
• Faulty pump contactor.
• Check both circ and feed pump
contactors for functionality.
• Replace pump contactor.
• Faulty wiring.
• Inspect the wiring for ground,
continuity, and proper voltage.
• Replace/Repair wiring.