STACK ST8130 Series Road Car Display Systems
Chapter 4. Configuring the Display System
Users Guide
19
Configurable Parameters
Configurable Parameters
The configurable parameters are displayed in the following order:
Configurable
Parameter
Setting Required
Switchable
Parameter
Shift RPM
RPM at or above which the gear shift light is to
come on
Yes
Low Fuel
Volume of fuel in tank at or below which the low
fuel warning light is to be turned on.
Yes
Ice Warning
Air temperature at or below which the Ice
Warning alarm is to be signalled
Yes
High OiI T
Oil temperature at or above which the High Oil T
alarm is to be signalled.
Yes
High Water
Water temperature at or above which the High
Water alarm is to be signalled.
Yes
Low Batt
Battery voltage at or below which the Low Batt
alarm is to be signalled.
Yes
Low Oil P
Oil pressure at or below which the Low Oil alarm
is to be signalled.
Yes
Fuel Tank
Sender
The volume of fuel currently in the tank. See
"Calibrating the Fuel Level", below, for more
details.
Not
Applicable
Gate RPM
Minimum RPM for oil temperature, oil pressure,
and water temperature warnings to operate.
Yes
E. S.
Cylinders
Number of cylinders in engine (for RPM)
Not
Applicable
W.S.
Pulses/Rev
See “Wheel Pulses and Circumferences” later in
this chapter for an explanation of how to
calculate the value to be used.
Not
Applicable
Wheel Cir
(mm) (ins)
See “Wheel Pulses and Circumferences” later in
this chapter for an explanation of how to
calculate the value to be used.
Not
Applicable