Configuring the Master and Slaves
33
15. Write the rest of the ladder logic.
Refer to section 7.2 and section 7.3 for information on the I, O and
M files.
16. Transfer the program to the SLC.
6.4
Using Windows 95 Hyperterminal to Access the
Scanner via the Serial Port
To access the scanner via the serial port:
1. Connect the AS-i scanner to the PC using the provided serial cable.
2. Start HyperTerminal and create a new connection.
3. For
Connect using:
, select
Direct to Com n
, where n is the serial port
you are using.
4. Select 38400 Bits per second, 8 Data bits, set Parity to None, select 1
Stop Bit, and set Flow control to None.
You should now be able to communicate with the scanner serial port. Once
you have configured the scanner, you can configure the AS-i slaves.