10-6
Parameter Specification Table
590+ Series DC Digital Converter
Tag
Name
MMI Menu
CE Block
Range
MN
Notes
186 FLD. QUENCH MODE SETUP PARAMETERS::FIELD CONTROL
Field Control
0:QUENCH
1:STANDBY
f6
187 RAW INPUT
SERIAL LINKS::SYSTEM PORT (P3)::P3
SETUP::5703 SUPPORT
5703
-300.00 to 300.00 %
f7
188 OVER SPEED LEVEL
SETUP PARAMETERS::CALIBRATION
Calibration
0.00 to 200.00 %
f8
4
189 SCALED INPUT
SERIAL LINKS::SYSTEM PORT (P3)::P3
SETUP::5703 SUPPORT
5703
f9
Output,2
190 PEAK HW SLOPE
RESERVED
Reserved
0 to -1
fa
2,4
191 BEMF FBK LEAD
SETUP PARAMETERS::FIELD
CONTROL::FLD.CURRENT
VARS::FLD.WEAK VARS
Field Control
10 to 5000
fb
192 BEMF FBK LAG
SETUP PARAMETERS::FIELD
CONTROL::FLD.CURRENT
VARS::FLD.WEAK VARS
Field Control
10 to 5000
fc
193 TICK LENGTH
RESERVED
Reserved
fd
Output,4
194 DISC ADAPT POT
RESERVED
Reserved
0 to 10000
fe
4
195 THRESHOLD (>)
SYSTEM::CONFIGURE I/O::DIGITAL
OUTPUTS::DIGOUT 1 (B5)
Digout 1 (B5)
-300.00 to 300.00 %
ff
2
196 THRESHOLD (>)
SYSTEM::CONFIGURE I/O::DIGITAL
OUTPUTS::DIGOUT 2 (B6)
Digout 2 (B6)
-300.00 to 300.00 %
fg
2
197 THRESHOLD (>)
SYSTEM::CONFIGURE I/O::DIGITAL
OUTPUTS::DIGOUT 3 (B7)
Digout 3 (B7)
-300.00 to 300.00 %
fh
2
198 P3 BAUD RATE
SERIAL LINKS::SYSTEM PORT (P3)::P3
SETUP
0:300
1:600
2:1200
3:2400
4:4800
5:9600
6:19200
fi
2
199 DELAY
SETUP PARAMETERS::INVERSE TIME
Inverse Time
0.1 to 600.0 SECS
fj
2,4
200 RATE
SETUP PARAMETERS::INVERSE TIME
Inverse Time
0.1 to 600.0 SECS
fk
2,4
201 REGEN MODE
SETUP PARAMETERS::CURRENT LOOP
Current Loop
0:2Q (NON-REGEN)
1:4Q (REGEN)
fl
2
202 INT. DEFEAT
SETUP PARAMETERS::SPEED LOOP
Speed Loop
Same as Tag 18
fm
203 INVERSE TIME O/P
DIAGNOSTICS
Inverse Time
fn
Output,2
204 AIMING POINT
SETUP PARAMETERS::INVERSE TIME
Inverse Time
0.00 to 103.00 %
fo
2,4
205 dI/dt
RESERVED
Reserved
0.00 to 200.00 %
fp
4
206 ENCODER
DIAGNOSTICS
Diagnostics
fq
Output
207 SPEED FEEDBACK
DIAGNOSTICS
Diagnostics
fr
Output
208 RATIO 0
SETUP PARAMETERS::SETPOINT SUM 1
Setpoint Sum 1
-3.0000 to 3.0000
fs
209 FLD.CTRL MODE
SETUP PARAMETERS::FIELD CONTROL
Field Control
0:VOLTAGE CONTROL
1:CURRENT CONTROL
ft
2
210 FLD.VOLTS RATIO
SETUP PARAMETERS::FIELD
CONTROL::FLD.VOLTAGE VARS
Field Control
0.00 to 100.00 %
fu
211 SYS HEALTH INHIB
RESERVED
Reserved
0x0000 to 0xFFFF
fv
2,4
212 OPERATING MODE
DIAGNOSTICS
Jog/Slack
fw
Output
213 ZERO CUR OFFSET
RESERVED
Reserved
0x0000 to 0xFFFF
fx
4
214 ZCD THRESHOLD
RESERVED
Reserved
0x0000 to 0xFFFF
fy
4
215 G&L POWER METER
RESERVED
Unallocated
fz
Output,4
216 PROG STOP LIMIT
SETUP PARAMETERS::STOP RATES
Stop Rates
0.0 to 600.0 SECS
g0
217 STOP LIMIT
SETUP PARAMETERS::STOP RATES
Stop Rates
0.0 to 600.0 SECS
g1
218 JOG SPEED 1
SETUP PARAMETERS::JOG/SLACK
Jog/Slack
-100.00 to 100.00 %
g2
219 JOG SPEED 2
SETUP PARAMETERS::JOG/SLACK
Jog/Slack
-100.00 to 100.00 %
g3
221 MMI FILTER T.C.
RESERVED
Reserved
0 to 20000
g5
4
222 PRED STEP
RESERVED
Reserved
0x0000 to 0xFFFF
g6
2,4
223 SCAN THRESHOLD
RESERVED
Reserved
0x0000 to 0xFFFF
g7
2,4
224 STALL TRIP DELAY
SETUP PARAMETERS::CALIBRATION
Calibration
0.1 to 600.0 SECS
g8