The Operator Station
5-13
590+ Series DC Digital Converter
How to Save, Restore and Copy your Settings
Saving Your Application
SYSTEM
CONFIGURE I/O
CONFIGURE I/O
ENABLED
CONFIGURE I/O
DISABLED
SYSTEM
CONFIGURE I/O
▼
M
E
▲
The PARAMETER SAVE menu, available in both the full and reduced
view levels, is used to save any changes you make to the MMI settings.
MENU LEVEL
PARAMETER SAVE
PARAMETER SAVE
UP TO ACTION
PARAMETER SAVE
REQUESTED
MENU LEVEL
PARAMETER SAVE
M
E
▲
Pressing the
▲
(UP) key, as instructed, saves all parameter values (with one exception, below)
in non-volatile memory, i.e. values are stored during power-down.
Note:
The local setpoint parameter value is not saved on power-down.
Restoring Saved Settings
If you are unsure about any changes you have made and you have not yet performed a
PARAMETER SAVE, simply switch the Converter off, and power-up again. The “last saved”
parameter settings will be restored.
Copying an Application
Copying an application requires a host computer connection to the Converter’s System Port
(P3). Information can then be downloaded to the computer (and uploaded to the Converter).
Refer to Chapter 14: “Serial Communications” for further information.
MMI Menu Map
1
SYSTEM
2
CONFIGURE I/O
CONFIGURE ENABLE
MMI Menu Map
1
PARAMETER SAVE
PARAMETER SAVE