Parameter Specification Table
10-5
590+ Series DC Digital Converter
Tag
Name
MMI Menu
CE Block
Range
MN
Notes
130 MODE
SERIAL LINKS::SYSTEM PORT (P3)::P3
SETUP
System Port P3
0:DISABLED
1:5703 MASTER
2:5703 SLAVE
3:EIASCII
dm
131 DEADBAND WIDTH
SETUP PARAMETERS::SETPOINT SUM 1
Setpoint Sum 1
0.00 to 100.00 %
dn
132 SETPT. RATIO
SERIAL LINKS::SYSTEM PORT (P3)::P3
SETUP::5703 SUPPORT
5703
-3.0000 to 3.0000
do
133 SETPT. SIGN
SERIAL LINKS::SYSTEM PORT (P3)::P3
SETUP::5703 SUPPORT
5703
Same as Tag 8
dp
134 SOURCE TAG
SYSTEM::CONFIGURE
I/O::CONFIGURE 5703
5703
0 to 639
dq
2,3
135 DESTINATION TAG
SYSTEM::CONFIGURE
I/O::CONFIGURE 5703
Scaled 5703
Input
0 to 639
dr
2,3
136 FEED FORWARD
SETUP PARAMETERS::CURRENT LOOP
Current Loop
0.10 to 50.00
ds
4
137 DISCONTINUOUS
SETUP PARAMETERS::CURRENT LOOP
Current Loop
0.00 to 200.00 %
dt
154 II
RESERVED
Reserved
ea
Output,4
155 VERSION NUMBER
SERIAL LINKS::SYSTEM PORT (P3)
Unallocated
eb
Output
158 OP STATION ERROR
RESERVED
Op Station
0x0000 to 0xFFFF
ee
1,4
161 AUX START
SETUP PARAMETERS::AUX I/O
Aux I/O
Same as Tag 18
eh
162 MIN MMI CYCLE TM
RESERVED
Reserved
A to 1388
ei
4
163 ILOOP PI MODE
RESERVED
Reserved
0 to 2
ej
2,4
164 TOGGLE PERIOD
RESERVED
Reserved
0x0000 to 0xFFFF
ek
4
165 TOGGLE REF 1
RESERVED
Reserved
-300.00 to 300.00 %
el
4
166 SEL. INT/CUR/SPD
RESERVED
Reserved
0 to 4
em
2,4
167 TOGGLE REF 2
RESERVED
Reserved
-300.00 to 300.00 %
en
4
168 AUX ENABLE
SETUP PARAMETERS::AUX I/O
Aux I/O
Same as Tag 18
eo
169 FIELD ENABLED
DIAGNOSTICS
Field Control
ep
Output
170 FIELD ENABLE
SETUP PARAMETERS::FIELD CONTROL
Field Control
Same as Tag 4
eq
2
171 SETPOINT
SETUP PARAMETERS::FIELD
CONTROL::FLD.CURRENT VARS
Field Control
0.00 to 100.00 %
er
172 INT. GAIN
SETUP PARAMETERS::FIELD
CONTROL::FLD.CURRENT VARS
Field Control
0.00 to 100.00
es
173 PROP. GAIN
SETUP PARAMETERS::FIELD
CONTROL::FLD.CURRENT VARS
Field Control
0.00 to 100.00
et
174 FLD. WEAK ENABLE
SETUP PARAMETERS::FIELD
CONTROL::FLD.CURRENT
VARS::FLD.WEAK VARS
Field Control
Same as Tag 4
eu
2
175 EMF LEAD
SETUP PARAMETERS::FIELD
CONTROL::FLD.CURRENT
VARS::FLD.WEAK VARS
Field Control
0.10 to 50.00
ev
176 EMF LAG
SETUP PARAMETERS::FIELD
CONTROL::FLD.CURRENT
VARS::FLD.WEAK VARS
Field Control
0.00 to 200.00
ew
177 EMF GAIN
SETUP PARAMETERS::FIELD
CONTROL::FLD.CURRENT
VARS::FLD.WEAK VARS
Field Control
0.00 to 100.00
ex
178 MAX VOLTS
SETUP PARAMETERS::FIELD
CONTROL::FLD.CURRENT
VARS::FLD.WEAK VARS
Field Control
0.00 to 100.00 %
ey
179 MIN FLD.CURRENT
SETUP PARAMETERS::FIELD
CONTROL::FLD.CURRENT
VARS::FLD.WEAK VARS
Field Control
0.00 to 100.00 %
ez
2
180 SPDFBK ALM LEVEL
SETUP PARAMETERS::CALIBRATION
Calibration
0.00 to 100.00 %
f0
181 UNFIL.FIELD FBK
DIAGNOSTICS
Calibration
f1
Output
182 FIELD I CAL.
SETUP PARAMETERS::CALIBRATION
Calibration
0.9800 to 1.1000
f2
183 FIELD DEMAND
DIAGNOSTICS
Field Control
f3
Output
184 FLD.FIRING ANGLE
DIAGNOSTICS
Field Control
f4
Output
185 FLD.QUENCH DELAY
SETUP PARAMETERS::FIELD CONTROL
Field Control
0.0 to 600.0 SECS
f5