118153-001 Rev. B
55
uX_Manual.doc REV -
8.3 uXHP80P100
Tabular information applies to the uXHP 80kV Model.
Digital to Analog Converter Scaling (Setpoints)
Analog to Digital Converter Scaling (Feedbacks, Monitors and Temperatures)
Analog Signal
Full Scale
(= 4095)
Scaling (LSB
Multiplier)
Notes:
kV Feedback
80.0kV
19.536 Volts/Bit
High Voltage output Monitor
kV Feedback 2
88.0kV
21.49 Volts/Bit
Auxiliary High Voltage output
Monitor
mA Feedback
6 mA
1.4652 uA/Bit
Output Current Monitor
Filament Current
3.6 A
0.87912 mA/Bit
Filament Current Monitor
Filament Voltage 5.5 V
0.001243 V/Bit
Filament Voltage Monitor
Control Board
Temperature
300 deg C 0.07326 C/Bit
Temperature Sensor: 10 mV/
Degree C
High Voltage Bd
Temperature
300 deg C 0.07326 C/Bit
Temperature Sensor: 10 mV/
Degree C max
Low Voltage
Supply Monitor
42.9V
0.10476 V/Bit
24V supply monitor
Setpoint Full
Scale
(= 4095)
Scaling (LSB
Multiplier)
Project Signal Name
kV Setpoint
80.0kV 19.536
V/Bit KV_PROG
mA SetPoint
5.0 mA
1.221 uA/Bit
MA_PROG
Filament
Preheat
10.0 A
2.442 mA /Bit
FIL_LIMIT_PROG
Filament
Limit
10.0 A
2.442 mA /Bit
FIL_PREHEAT
Summary of Contents for uX SERIES
Page 11: ...uX MANUAL 4 118151 001 REV A Figure 2 1 50kV uX DIMENSIONS ...
Page 12: ...uX MANUAL 5 118151 001 REV A Figure 2 2 65kVuX DIMENSIONS ...
Page 16: ...uX MANUAL 9 118151 001 REV A Table 3 2 DC Input Filament Connections ...
Page 17: ...uX MANUAL 10 118151 001 REV A Figure 3 3 Monitors Voltage Current Control Connections ...
Page 18: ...uX MANUAL 11 118151 001 REV A Figure 3 4 Recommended Interlock HV on Configurations ...