118153-001 Rev. B
27
uX_Manual.doc REV -
5.4
Control Command Overview
The following table summarizes the control commands for the uX unit.
Command Name
<CMD>
<ARG>
RANGE
Change Baud Rate
7
1 ASCII
0-5
Program DAC Channel
A
10
1-4 ASCII
0-4095
Program DAC Channel
B
11
1-4 ASCII
0-4095
Program DAC Channel
D
12
1-4 ASCII
0-4095
Program DAC Channel
C
13
1-4 ASCII
0-4095
Request DAC A
Setpoint
14
None
-
Request DAC B
Setpoint
15
None
-
Request DAC D
Setpoint
16
None
-
Request DAC C
Setpoint
17
None
-
Request Analog
Readbacks
Channels 7 – 15
19
None
-
Request Analog
Readbacks
Channels 0 – 6
20
None
-
Request HV On Hours
Counter
21
None
-
Request Status
22
None
-
Request Software
Version
23
None
-
Request Hardware
Version
24
None
-
Request Model
Number
26
None
-
Reset HV On Hours
Counter
30
None
-
Request Expanded
Status
32
None
-
Reset Faults
52
None
-
Request Aux KV
Feedback
65
None
-
Request SVN Revision
66
None
-
Program High Voltage
Status
99
1 ASCII
0 or 1
Summary of Contents for uX SERIES
Page 11: ...uX MANUAL 4 118151 001 REV A Figure 2 1 50kV uX DIMENSIONS ...
Page 12: ...uX MANUAL 5 118151 001 REV A Figure 2 2 65kVuX DIMENSIONS ...
Page 16: ...uX MANUAL 9 118151 001 REV A Table 3 2 DC Input Filament Connections ...
Page 17: ...uX MANUAL 10 118151 001 REV A Figure 3 3 Monitors Voltage Current Control Connections ...
Page 18: ...uX MANUAL 11 118151 001 REV A Figure 3 4 Recommended Interlock HV on Configurations ...