68
Operating instructions BMK-20i | Heinz Soyer Bolzenschweißtechnik
Setting the lift height with the stud welding device
Step 4:
Place the gun on the workpiece and
press the release button on the gun
for the weld.
The currently set value for the drop
time in [ms] appears on the display.
The longer the drop time, the higher
the lift height.
Determining the correct lift height/drop time requires experience and
some trials. Guide values for the correct drop time can be found in
chapter
“11.1.1 Support tables for device settings on page 62.
The lift height/drop time is changed using the
adjustment ring on the welding gun for the lift
height of the stud. Pull out the adjustment ring
and turn it to change the setting.
After you have changed the setting, push the
adjustment ring back in.
Step 5:
Make sure the device is in the operating mode by selecting one of the
three functions above (green LEDs).
Notes on "Setup" mode
The setup process can be repeated as often as required. However, to avoid the
magnetic coil overheating, maintain a waiting time of approx. one second between two
test strokes.