How to retrofit the PH-2L and PH-4L stud welding guns to drawn arc stud welding with
ceramic ferrule
Step 1:
Switch off the stud welding device when the gun is connected to
it.
Step 2:
If the gun is equipped with a support,
remove it if need be. To this end, loosen
the two Allen screws.
It is not essential to remove the
support, however, this makes use
easier.
Step 3:
It may be necessary to remove a
screwed-on adapter or stud chuck.
Step 4:
Select a suitable stud chuck according to
the stud dimension. Screw on the stud
chuck.
Step 5:
The stud chuck must be tightly
screwed.
When
the
screwed
connection is not tight enough, there
is a risk of scorching during the
welding process.