PIX 260i User Guide
v. 2.10
Features and specifications are subject to change. Visit www.sounddevices.com for the latest documentation.
78
Se
tup Menu Op
tions
Network
#
Parameter Name
Description
Options
1
This PIX’s Name
Sets name of PIX 260i. This must be unique within a
network.
» PIX260
2
Grouping
Sub-menu for network grouping settings.
2.1
Network Group
Groups with other PIX 250i, PIX 260i, PIX 270i, and
970 units on the network.
» No Group
• Group 1
• Group 2
• Group 3
• Group 4
2.2
Push Settings to Group
Copies this unit’s settings to all other units in the
group. All grouped settings will be pushed. (
2.3
Synchronize audio channel
settings
3
Dante Redundancy Mode
When On the PIX 260i’s Primary and Secondary
Ethernet ports both transmit Dante Audio over sepa-
rate networks. This provides a fail safe of the Dante
system if one of the networks should fail.
In Dante
Redundancy Mode, two separate networks
must be run and they CANNOT be connect-
ed to one another. Connect any computer
running Dante Controller to the PIX 260’s
PRI Ethernet network.
» Off
• On
4
Auto IP Settings
When On, the IP settings will automatically be pro-
vided by a DHCP (recommended), or Link-local when
no DHCP is present. When Off the IP Address, Subnet
Mask, and Gateway will have to be entered manually.
• Off
» On
5
IP Address
Displays IP Address, can be edited when Auto IP
Settings is OFF.
6
Subnet Mask
Displays Subnet Mask, can be edited when Auto IP
Settings is OFF.
7
Gateway
Displays Gateway, can be edited when Auto IP Set-
tings is OFF.
8
Authentication
Set the user name and password to be used for
PIXNET and Samba drive access.
System
#
Parameter Name
Description
Options
1
Power
Determines power on and off method. When set to
Always on, the PIX 260i will turn on and off when
external DC is applied. When Use Power Switch is
selected the PIX 260i is powered on and off using a
key combination of AUDIO + Control Knob press.
• Always On
» Use Power Switch
2
Initial View
Sets which one of three screens will appear after the
unit boots up.
» Main View (video)
• AudioView (with Input Settings)
• Audio View (with expanded
meters)
3
HP Warning Bell Level
Adjusts the level of the heaphone warning bell sound
» -40dBFS
(Off, -60 to -12dBFS)
4
Time Zone
Selects the international time zone
» (GMT-06:00) Central Time (US)
(All GMT zones)
5
Daylight Saving
Toggles daylight saving on or off for the time-of-day
clock
» Off