SVP 0/1/2/3-E - Code: 3529.0091.01
Rev. 0
dated 19/06/2001
16-III
PT
601
PP
601
GC
601
Technical Assistance Service
Tel. (+39) 0445.595.111
15
3.4
Machine installation
3.4.1
Installation warnings
Position the machine so that the free length of power cable from the
machine to the socket is as short as possible.
3.4.2
Notes for the electrical installation personnel
The electrical installer must be qualified and experienced in carrying out
work of this nature and should therefore be aware of the various technical
notions and applicable standards to guarantee high standards of
workmanship.
Hook-up of the machine to the bakery electrical installation must be carried
out in compliance with the established regulations and prescriptions with
reference to the information and instructions contained in the present
handbook. For this work the machine is supplied with a CEI 20-22 electrical
cable and an EC standard plug with as many poles as indicated on the
machine dataplate. The machine must be connected to a proper and
efficient earthing plant. Do not use makeshift solutions by connecting the
earth to water pipes, gas pipes or other metal structures.
The power feeding cable must be kept well clear of heated surfaces and
moving parts. It must also be installed in such a way that it does not present
an obstruction to the movement of personnel and materials in the bakery.
Caution!
Before lifting the machine, make sure that the lifting ropes and lifting
equipment are of suitable load capacity in relation to the weight of
the machine.
Caution!
When lifting and lowering the machine, the ascent and descent
movements must be as gradual and smooth as possible, avoiding
jerkiness and sudden increases in kinetic energy that are difficult to
withstand when the movement is stopped suddenly.
Caution!
Make sure that line voltage is the same as the voltage required by the
machine as clearly shown on the machine dataplate (heading 2.4).