Cha
p
te
r 3
Pre
par
at
ion
s
32
3-1 Connections and Settings
recording from the RM-280 (when XDCAM mode is
selected).
RM-280 settings
EDITOR/REMOTE CONTROL switch: REMOTE
CONTROL
Setup menu item 19 “FNC MODE”: XDCAM
For information about function assignments to PF keys in
XDCAM mode, refer to the Operation Manual for the RM-
280.
PDW-R1 settings
: REMOTE
Extended menu item 214 “REMOTE INTERFACE”:
9PIN
3-1-7 Editing Control Unit Settings
When connecting an editing control unit to use with this
unit, make the following settings, depending on the editing
control unit model.
BVE-600/700/900/910/2000/9100
Set VTR constants as follows.
FXE-100/120
Set VTR constants as follows.
RM-450
Set the DIP switches as follows.
• Left switch
• Right switch
PVE-500
No settings required.
Line
mode
VTR CONSTANT 1
1
2
3
4
5
6
7
8
525/60 A0
92
00
96
05
05
03
80
625/50 A1
92
00
7D
05
05
03
80
Line
mode
VTR CONSTANT 2
1
2
3
4
5
6
7
8
525/60 0A
07
FE
00
80
5A
FF
5A
625/50 0A
07
FE
00
80
4C
FF
4B
Line
mode
1
2
3
4
5
6
7
8
525/60 A0
92
00
96
05
05
03
80
625/50 A1
92
00
7D
05
05
03
80
Line
mode
9
10
11
12
13
14
15
525/60 0A
07
FE
00
80
5A
FF
625/50 0A
07
FE
00
80
4C
FF
Line
mode
7
6
5
4
3
2
1
0
525/60
OFF –
–
OFF –
–
–
–
625/50
OFF –
–
OFF –
–
–
–
Line
mode
7
6
5
4
3
2
1
0
525/60
OFF –
OFF ON
OFF OFF ON
ON
625/50
ON
–
OFF ON
OFF OFF ON
ON