Associating a GPIO channel (only an output pin) with an Automation command
The signal output to a theater facility control system can be executed as the Automation command by
associating a GPIO channel (only output pin) with an Automation command. The Automation command
can be manually accessed from a “Status” tab
→
Auditorium screen or inserted into SPL as a cue.
1. Tap
[New]
in the Automation pane.
The New Automation screen is displayed.
2. Enter data in Automation Name and select the GPIO channel (only output pin) to be associated.
The alphanumeric characters can be used as the Automation Name (up to 100 characters).
n
An Automation command must be associated for each level when the type of a trigger is set to Level
in GPIO Profile.
In “State” on the New Automation screen, click the On or Off check box.