5-23 (E)
SRX-R515P
Control Mode setting
In the Control Mode pane, the luminance information to be registered in the function memory is set.
.
Lamp Power: The lamp power value (level and fine adjustment value) that has been set is registered in
the function memory.
.
Luminance: The luminance at that time is registered in the function memory (not the lamp power
setting value (level and fine adjustment value) that has been set). When the registered
function memory is called, the lamp power value (level and fine adjustment value) is
automatically adjusted so that the luminance becomes the same level as the luminance at
that time.
5-7-6. Registration of Adjustment Result (FUNCTION MEMORY Function)
The adjustment and setting data can be registered on this system. In general, the adjustment, setting and
registration are performed for each signal types (2D/3D, field angle (HD/scope/flat)) of contents to be
reproduced. The registered data is called when the contents are reproduced.
n
When the projector is in standby state displaying the test pattern, the registration and calling of function
memory cannot be performed.
1. After the adjustment and setting are completed, tap the “Configuration” tab.
2. Tap
[Projector|$2D%]
→
[Set|Function]
.
The Set Function screen is displayed.
3. Select the function memory that you want to register from Function List pane on the Projector (2D)
screen, then tap
[Save]
.
4. Type the function name and tap
[Apply]
.
The alphanumeric characters and symbols can be used as the function name (up to 32 characters).
Screen example
[Save]
[Set|Function]
[Projector|$2D%]