3-6 (E)
SRG-300SE/301SE
3-5. IP Image Trouble
What kind of symptoms are
there?
Is the symptom improved
after restarting this unit?
An error is displayed and
image is not displayed.
Capturing and recording
of still image cannot be
performed.
The image is flipped
upside down.
The image is not
reproduced smoothly.
Block noise appears.
Set the browser security
level correctly.
(Refer to the user’s guide.)
Set the image inversion
correctly in the camera
setting menu.
Confirm the performance
specification of PC.
Confirm the setting menu
of the camera image, and
use this unit by lowering
the bit rate and frame rate
of codec.
No
Is the symptom
improved?
No
Is the fine-wire coaxial cable
between the SY-437 board and
MD-156 board, MD-156 board
and CN-3766 board, and
CN-3766 board and FCB
assembly connected correctly?
Connect the fine-wire coaxial
cable correctly.
If there is any abnormality,
replace it. (Refer to Section 5.)
No
Replace the FCB assembly or
SY-437 board.
FCB assembly: Refer to Section 1-4-2.
SY-437 board: Refer to Section 1-4-5.
There is a problem in the
firmware of this unit.
Perform the firmware version
upgrade. (Refer to Section 2-2-4.)
Yes
Yes
Yes
Reset this unit to the
factory setting.
(Refer to Section 2-1-6.)