2-26 (E)
SRG-300SE/301SE
2-8-2. Writing of FCB Adjustment Data
Procedure
1. Connect the devices as follows.
2. Turn on the power of this unit.
3. Wait until the image is output on the SDI monitor.
4. Change the IP address of this unit and PC according to Section 2-1-3.
5. Check the image by accessing this unit from PC according to Section 2-1-4.
6. Perform the following CGI command according to Section 2-1-5 to write the adjustment data of FCB
EEPROM.
CGI
command:
http://192.168.0.100/factory/prima-factory.cgi?CameraAdjustSetting=on
User
name:
primana
Password:
primana
t
After the command is executed, the color and brightness of the camera image will change.
7. After the command is executed, wait for 120 seconds. Check that the image is not inversed and that
there is no abnormality in the image when the unit is placed in normal setting position.
n
If the power is turned off before the completion of the command, the normal image may not be out-
put. Be sure to wait for at least 120 seconds and check that there is no abnormality in the image.
End
1. Reset this unit to the factory setting according to Section 2-1-6.
2. Turn off the power of each device and disconnect the connections.
PC
This unit
SDI monitor
LAN cable
BNC cable