2-8 (E)
SRG-300SE/301SE
2-1-5. How to Execute the CGI Command
You can execute the CGI command by typing it in the address bar of Internet Explorer.
1. Type the CGI command in the address bar of Internet Explorer, and then press the
[Enter]
key of the
PC keyboard.
2. When the user name and password are requested, type the user name and password corresponding to
the CGI command, and then click the
[OK]
button.
2-1-6. Resetting to Factory Setting
1. Turn off the power of this unit.
2. Turn on the power of this unit while pushing the reset switch (S901/SW-1654 board) in the rear
portion of this unit using the tool having a long and thin tip.
3. The NETWORK indicator of this unit is lit in amber for a while, which is different from the normal
power ON state.
After a period of time, the resetting is started and each indicator repeats blinking in the following sequence.
NETWORK: Lights up in green.
→
Lights up in yellow.
→
OFF
→
Lights up in green.
→
Lights
up in amber
→
OFF
POWER:
Lights up in green.
→
OFF
→
Lights up in green.
→
OFF
→
Lights up in green.
→
OFF
When the resetting is completed, each indicator is lit as follows and the image is output on the SDI
monitor.
NETWORK: stays lit in green.
POWER:
stays lit in green.
4. Click
the
[Search]
button in the SNC toolbox, and check that this unit is set to DHCP.
5. Exit the SNC toolbox.
Type the CGI command and
press the
[Enter]
key.
Check that DHCP is displayed.
[Search]
button
[OK]
button
User name
Password
Summary of Contents for SRG-300SE
Page 1: ...HD COLOR VIDEO CAMERA SRG 300SE SRG 301SE SERVICE MANUAL 1st Edition ...
Page 6: ......
Page 70: ......
Page 83: ......