– 10 –
5. Brightness Adjustment
Set the VIDEO signal level that drives the LCD to proper value.
If deviated, the LCD screen will be unclear, black blurring, or white
blurring.
Item number
3-01-04
Screen display
10-step gradation pattern (white/black)
Measurement point
Adjusting monitor jig
G
pin (VG)
Measuring instrument
Oscilloscope
Adjustment data
7C
initial value
Adjustment value
A = 1.40
±
0.05 Vp-p
Note:
This is the tracking adjustment in relation to “6. Contrast
Adjustment”.
Adjusting method
1) Select major item number “2” (EVF), and set the 10-step gra-
dation pattern (white/black).
2) Select the item number “3-01-04”.
3) Press the DSPL key to display the 10-step gradation pattern
(white/black) on the LCD screen.
4) Connect the adjusting monitor jig
A
pin (XTST) and
E
pin
(GND).
5) Using
e
and
E
keys, change the adjustment data so that the
voltage (A) between pedestal (0 IRE) and GAMMA1 limiter
level satisfies the adjustment value.
6) Press
y
key to write the adjustment data.
7) Disconnect the adjusting monitor jig
A
pin (XTST) and
E
pin (GND).
8) Press the DSPL key to return the LCD screen to the test mode
screen.
9) Check that the adjustment value of “Contrast Adjustment” is
satisfied.
If not satisfied, perform “Contrast Adjustment”.
Fig.7-1-13
Pedestal(0 IRE)
GAMMA1
limiter level
A
2H
4. RGB D Range Adjustment
Set the D range of RGB decoder driver step-wise output that drives
the
LCD to proper value.
If deviated, the LCD screen will be black blurring or white blur-
ring.
Item number
3-01-03
Screen display
10-step gradation pattern (white/black)
Measurement point
Adjusting monitor jig
G
pin (VG)
Measuring instrument
Oscilloscope
Adjustment data
80
initial value
Adjustment value
A = 3.00
±
0.05 Vp-p
Adjusting method
1) Select major item number “2” (EVF), and set the 10-step gra-
dation pattern (white/black).
2) Select the item number “3-01-03”.
3) Press the DSPL key to display the 10-step gradation pattern
(white/black) on the LCD screen.
4) Using
e
and
E
keys, change the adjustment data so that the
voltage (A) between pedestal of inverted waveform and ped-
estal of non-inverted waveform satisfies the adjustment value.
5) Press
y
key to write the adjustment data.
6) Press the DSPL key to return the LCD screen to the test mode
screen.
Fig.7-1-12
2H
Pedestal
Pedestal
A
Summary of Contents for MDDISCAM DCM-M1
Page 5: ...1 1 SECTION 1 GENERAL This section is extracted from in struction manual 3 866 152 11 DCM M1 ...
Page 6: ...1 2 ...
Page 7: ...1 3 ...
Page 8: ...1 4 ...
Page 9: ...1 5 ...
Page 10: ...1 6 ...
Page 11: ...1 7 ...
Page 12: ...1 8 ...
Page 13: ...1 9 ...
Page 14: ...1 10 ...
Page 15: ...1 11 ...
Page 16: ...1 12 ...
Page 17: ...1 13 ...
Page 18: ...1 14 ...
Page 19: ...1 15 ...
Page 20: ...1 16 ...
Page 21: ...1 17 ...
Page 22: ...1 18 ...
Page 23: ...1 19 ...
Page 24: ...1 20 ...
Page 25: ...1 21 ...
Page 26: ...1 22 ...
Page 27: ...1 23 ...
Page 28: ...1 24 ...
Page 29: ...1 25 ...
Page 30: ...1 26 ...
Page 31: ...1 27 ...
Page 32: ...1 28 ...
Page 33: ...1 29 ...
Page 34: ...1 30 1 30 E ...
Page 47: ...2 13 MEMO ...
Page 69: ...DCM M1 4 5 4 6 4 7 4 8 4 1 FRAME SCHEMATIC DIAGRAM FRAME ...
Page 96: ...DCM M1 4 115 4 113 4 114 ETHER INTERFACE ETHER ...