6-60
HVR-HD1000J/HD1000U/HD1000N/HD1000E/HD1000P/HD1000C
30. White Defect Check
RadarW
RadarW
RadarW
RadarW
RadarW
Subject
Not required
Measurement Point
Adjusting remote commander
Measuring Instrument
Specified value 1
Data of page: 6 address: D1 is “00”
Specified value 2
Data of page: 6, address: D2 is “00”
to “08”
Note 1:
Perform “White Defect Adjustment” before this adjust-
ment.
Note 2:
Perform adjustments successively, starting from the “HS
White Defect Adjustment”.
Note 3:
The lens thermistor data of the set must exceed 37 de-
grees.
If not, perform the aging in the aging temperature judge
mode until the set exceeds 37 degrees.
Note 4:
Check that the data of page: 0, address: 10 is “00”.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
02
Check the data is “00”.
(Note 5)
3
6
E0
Check the data is “25” to
“50”. (Note 6)
4
6
07
Check the data is “04”.
5
6
D0
04
6
6
01
21
Press PAUSE (Write) button.
7
6
02
Check the data changes to
“01”.
8
6
D1
Check the data is “00”.
9
6
D2
Check the data is “00” to
“08”.
Note 5:
If not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Note 6:
If the data is other than “25” to “50”, perform the aging.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
0
01
00
31. Black Defect Adjustment
RadarW
RadarW
RadarW
Defect black defective pixels of CMOS image sensor.
Subject
Clear chart (All white) (Note 1)
Note 1:
Perform “White Defect Adjustment” before this adjust-
ment.
Note 2:
Perform adjustments successively, starting from the “HS
White Defect Adjustment”.
Note 3:
The lens thermistor data of the set must exceed 37 de-
grees.
If not, perform the aging in the aging temperature judge
mode until the set exceeds 37 degrees.
Note 4:
Shoot the clear chart with the zoom TELE end.
Note 5:
Check that the data of page: 0, address: 10 is “00”.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
Adjusting method:
Order Page Address Data
Procedure
1
Turn off the power and turn
on again.
2
0
01
01
3
6
02
Check the data is “00”.
(Note 6)
4
6
E0
Check the data is “25” to
“50”. (Note 7)
5
6
07
Check the data is “04”
6
6
2C
01
7
6
90
00
8
6
91
04
9
6
92
00
10
6
93
10
11
6
01
79
Press PAUSE (Write) button.
12
Wait for 1.5 seconds.
13
Check that the entire screen
is white.
14
6
D0
01
15
6
01
21
Press PAUSE (Write) button.
16
6
02
Check the data changes to
“01”.
Note 6:
If not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Note 7:
If the data is other than “25” to “50”, perform the aging.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
6
90
00
3
6
91
00
4
6
92
00
5
6
93
00
6
6
01
79
Press PAUSE (Write) button.
7
Wait for 1.5 seconds.
8
6
01
00
Press PAUSE (Write) button.
9
6
2C
00
10
0
01
00
Ver. 1.2 2008.04