6-42
HVR-HD1000J/HD1000U/HD1000N/HD1000E/HD1000P/HD1000C
14. Linear Matrix Adjustment (2)
RadarW
RadarW
RadarW
Adjust the matrix coefficient for compensating the variation in
spectral sensitivity.
Adjustment Page
6F
Adjustment Address
60 to 71, C8 to EB
Note 1:
If reading/writing data on pages 6F, set data: 06 to page:
0, address: 10, and then select pages: F. By this data set-
ting, the pages 6F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 0, address: 10, and set data: 06.
3) Input the following data to page: F (6F), address: 60 to 71, C8
to EB.
Note 2:
Press the PAUSE (Write) button of the adjustment remote
commander each time to set data.
4) Select page: 0, address: 10, and set data: 00.
5) Select page: 0, address: 01, and set data: 00.
Address
Data
NTSC PAL
60
21
21
61
78
78
62
02
02
63
BC
BC
64
FE
FE
65
34
34
66
FF
FF
67
E9
E9
68
20
20
69
2D
2D
6A
FF
FF
6B
AF
AF
6C
FF
FF
6D
36
36
6E
05
05
6F
0A
0A
70
1D
1D
71
9D
9D
C8
03
03
C9
BF
BF
CA
FF
FF
CB
A6
A6
CC
00
00
CD
32
32
CE
00
00
CF
0E
0E
D0
03
03
Address
Data
NTSC PAL
D1
E5
E5
D2
00
00
D3
25
25
D4
00
00
D5
17
17
D6
FF
FF
D7
55
55
D8
04
04
D9
7F
7F
DA
04
04
DB
45
45
DC
00
00
DD
5B
5B
DE
FF
FF
DF
CE
CE
E0
FF
FF
E1
F3
F3
E2
04
04
E3
15
15
E4
FF
FF
E5
E0
E0
E6
FF
FF
E7
E9
E9
E8
00
00
E9
9A
9A
EA
03
03
EB
8B
8B