6-33
HVR-HD1000J/HD1000U/HD1000N/HD1000E/HD1000P/HD1000C
4.
MR Adjustment
RadarW
RadarW
RadarW
The inner focus lens MR adjustment is carried out automatically.
In whichever case, the focus will be deviated during auto focus-
ing/manual focusing.
Subject
Not required
Measurement Point
Adjusting remote commander
Measuring Instrument
Adjustment Page
6F
Adjustment Address
30, 40 to 4F
Specified value
Data of page: 6, address: 0C is “00”.
Note 1:
Perform the adjustment with the lens in horizontal state.
Note 2:
Perform “Flange Back Adjustment” after this adjustment.
Note 3:
If reading/writing data on pages 6F, set data: 06 to page:
0, address: 10, and then select pages F. By this data set-
ting, the pages 6F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
02
Check the data is “00”.
(Note 4)
3
Wait for 2 seconds.
4
6
01
BD
Press PAUSE (Write) button.
(Note 5)
5
6
02
Check the data changes to
“01”.
6
6
0C
Check the data is “00”.
Note 4:
If not, select page: 6, address: 01, set data: 00, and press
the PAUSE (Write) button.
Note 5:
The adjustment data will be automatically input to page:
6F, address: 30, 40 to 4F.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
6
01
25
Press PAUSE (Write) button.
3
Wait for 2 seconds.
4
6
02
Check the data changes to
“01”.
5
6
01
00
Press PAUSE (Write) button.
6
0
01
00
3.
HALL Adjustment (2)
RadarW
RadarW
RadarW
For detecting the position of lens iris and ND filter, adjust the hall
AMP gain and offset.
Subject
Not required
Measurement Point
Measuring Instrument
Adjusting remote commander
Adjustment Page
69
Adjustment Address
D0 to D8
Specified value
Data of page: 6, address: 0C is “00”
Note 1:
If reading/writing data on pages 69, set data: 06 to page:
0, address: 10, and then select pages 9. By this data set-
ting, the pages 69 can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
02
Check the data is “00”.
(Note 2)
3
6
D0
22
4
6
01
6D
Press PAUSE (Write) button.
(Note 3)
5
6
02
Check the data changes to “01”.
6
6
0C
Check the data is “00”.
Note 2:
If not, select page: 6, address: 01, set data: 00, and press
the PAUSE (Write) button.
Note 3:
The adjustment data will be automatically input to page:
69, address: D0 to D8.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
0
01
00